Generated by Rank Math SEO, this is an llms.txt file designed to help LLMs better understand and index this website. # Ulpatek: Ulpatek is an air filtration manufacturer founded in 2007 in İstanbul, Türkiye. It produces coarse and fine dust filters, EPA, HEPA and ULPA filters, gas-phase filtration products, filter housings and cleanroom equipment, and exports to more than 80 countries. Filters are tested in the company's own ULPALAB laboratory to EN 1822, ISO 29463 and ISO 16890. ## Sitemaps [XML Sitemap](https://www.ulpatek.com/sitemap_index.xml): Includes all crawlable and indexable pages. ## Posts - [Dust Storms, Sand and Heat: Air Filter Selection for Harsh Climates](https://www.ulpatek.com/filter-technology/dust-storm-sand-heat-air-filter-selection/): Use the site's dust, temperature, moisture and loading profile to select filters and plan maintenance around periods of heavy exposure. - [Eurovent Energy Classes A+ to E: Read the Right kWh Limit Before Comparing Prices](https://www.ulpatek.com/filter-technology/eurovent-filter-energy-classes-kwh-limits/): Compare energy letters within the correct efficiency band, then read the rated kWh and cost assumptions behind the label. - [“Do You Have a Food-Grade Certificate?” Is the Wrong Starting Question for an HVAC Filter](https://www.ulpatek.com/filter-technology/food-grade-certificate-hvac-air-filter/): Replace a vague food-grade certificate request with clear information about the application, product exposure, filter construction and evidence needed. - [Why E10, E11 and E12 Filters Ship Without a Scan Test](https://www.ulpatek.com/filter-technology/why-e10-e11-e12-filters-have-no-scan-test/): Understand why E10–E12 classification does not carry the HEPA local scan requirement, and request the performance evidence appropriate to the filter. - [Fan Filter Unit or HEPA Terminal Box: How to Choose Terminal Filtration for Your Cleanroom](https://www.ulpatek.com/filter-technology/fan-filter-unit-vs-hepa-terminal-box/): Compare fan filter units and terminal boxes at the same duty, including pressure budgets, controls, maintenance access and system energy. - [Does a HEPA Filter Need CE Marking? Start With the Product, Not the Certificate](https://www.ulpatek.com/filter-technology/does-hepa-filter-need-ce-marking/): Start with the supplied product and its intended use to separate filtration evidence from the conformity requirements for powered equipment. - [The Real Cost of an Air Filter: A Worked TCO Example with Every Assumption Shown](https://www.ulpatek.com/filter-technology/air-filter-total-cost-ownership-calculation/): Work through filter energy, purchase and maintenance costs with every assumption stated, then see where the more expensive filter breaks even. - [What Is the Maximum Operating Temperature of a HEPA Filter? Continuous vs Peak, Gasket and Separator Limits](https://www.ulpatek.com/filter-technology/hepa-filter-maximum-operating-temperature/): Check the complete filter's continuous and peak temperature limits, including seals, separators and the airflow basis used for the hot process. - [How to Read a HEPA Filter Test Certificate, Line by Line](https://www.ulpatek.com/filter-technology/how-to-read-hepa-filter-test-certificate/): Read serial numbers, airflow, MPPS and local results in the right order, with an illustrative H14 report to explain common mistakes. - [When to Change a HEPA Filter: Pressure Drop, Time or Test Result?](https://www.ulpatek.com/filter-technology/when-to-change-hepa-filter/): Separate resistance, airflow, integrity and calendar triggers when setting a replacement rule, and understand why requalification does not mean automatic replacement. - [Eurovent 4/23: Are You Still Using the Old ODA/SUP Table?](https://www.ulpatek.com/filter-technology/eurovent-4-23-oda-sup-filter-selection/): Use the ODA/SUP table to select filter stages, check combined efficiency and understand the limits behind the recommendation. - [Replacing a HEPA Filter in an Existing Housing: The 6 Dimensions and 3 Gasket Checks to Confirm Before You Order](https://www.ulpatek.com/filter-technology/replacement-hepa-filter-dimensions-gasket-checklist/): Confirm the frame dimensions, gasket geometry and operating duty before ordering a replacement for an existing HEPA housing or terminal box. - [H13 or H14? A HEPA Filter Decision Guide by Application](https://www.ulpatek.com/filter-technology/h13-or-h14-hepa-filter-decision-guide/): Choose between H13 and H14 by checking the application, required evidence and pressure drop, without confusing filter class with room classification. - [The HEPA Filter Isn’t Leaking — Your Housing Is](https://www.ulpatek.com/filter-technology/hepa-filter-housing-gasket-leaks/): Separate filter-media defects from gasket and housing leaks by checking the leak location, sealing interface and test conditions together. - [Visit 360 Showroom Online!](https://www.ulpatek.com/visit-360-showroom-online/): We are always delighted to welcome you to our factory. However, if you’re short on time, we invite you to explore our showroom online! - [ULPATEK stands out with Filter and Filtration Solutions in 2023](https://www.ulpatek.com/ulpatek-stands-out-with-filter-and-filtration-solutions-in-2023/): ULPATEK continued its growth in terms of revenue in 2023, while also drawing attention with its steps in customer satisfaction, innovation, and sustainability. - [ULPATEK Filter Continues to Grow by Increasing Production Capacity with New Investments](https://www.ulpatek.com/ulpatek-filter-continues-to-grow-by-increasing-production-capacity-with-new-investments/): ULPATEK Filter, as a filter manufacturer that serves a wide range from the simplest ventilation systems to clean rooms, has made significant investments in 2022 and fully commissioned them in 2023. The company manufactures according to ISO 16890 and ISO 29463 (EN 1822) standards in its modern facility, using the most advanced machines in the filtration field. - [We look forward to welcoming you at our stand.](https://www.ulpatek.com/sodex2021/): ISK-SODEX ISTANBUL - [Ulpatek Has Met the Expectations in Combating the Pandemic](https://www.ulpatek.com/ulpatek-has-met-the-expectations-in-combating-the-pandemic/): Ferhat GÜRER, Ulpatek Air Filter’s Export Sales Manager, shared the operations of Ulpatek Air Filter in 2020 and their goals for 2021.Stating that our lives were negatively affected due to the Covid-19 pandemic in 2020, Ferhat GÜRER added, "We, as Ulpatek Air Filter, have met the expectations of the industry by fulfilling our responsibilities for the filtration issue, the primary subject in combating the pandemic in 2020." - [Can HEPA Filters Capture the Coronavirus?](https://www.ulpatek.com/can-hepa-filters-capture-the-coronovirus/): Regarding the Coronavirus (COVID-19) epidemic, the most common question asked about filtration is that “Can HEPA Filter capture the viruses?” The answer to the question; Yes, HEPA Filters captures the viruses within their efficiency value. - [Ulpatek distribute emergency kit to its employes](https://www.ulpatek.com/ulpatek-distribute-emergency-kit-to-its-employes/): ULPATEK continues to inform and support its employees within the framework of its social company approach. - [Ulpatek was at the INTERCLIMA PARIS fair!”](https://www.ulpatek.com/ulpatek-was-at-the-interclima-paris-fair/): Staying true to its sustainable growth plan, Ulpatek participated in the INTERCLIMA PARIS fair held with National Participation between November 5th and 8th in France to strengthen its existing connections and establish new ones. - [Thank you for visiting our booth at the SODEX 2019 fair!](https://www.ulpatek.com/thank-you-for-visiting-our-booth-at-the-sodex-2019-fair/): We would like to thank the Deputy Minister of Industry and Technology of the Republic of Turkey, Mr. Hasan Büyükdere, and the President of the Turkish Exporters Assembly (TİM), Mr. İsmail Gülle, for visiting our booth at the SODEX 2019 fair. - [You are invited to the seminar of ULPATEK Filter at the SODEX Fair!](https://www.ulpatek.com/you-are-invited-to-the-seminar-of-ulpatek-filter-at-the-sodex-fair/): As Ulpatek Filter, we continue to share our expertise in proper filtration with the HVAC industry. - [ULPATEK Filter increased the number of countries it exports to to 70](https://www.ulpatek.com/ulpatek-filter-increased-the-number-of-countries-it-exports-to-to-70/): ULPATEK Filter, with its remarkable projects in the Canary Islands and the Maldives, providing solutions to the filtration needs of the HVAC sector, has increased the number of countries it exports to to 70. - [ULPATEK Filter continues its R&D work at ULPALAB test laboratory](https://www.ulpatek.com/ulpatek-filter-continues-its-rd-work-at-ulpalab-test-laboratory/): ISO 16890 Test DeviceFor the first time in Turkey, ULPATEK continues its product development efforts by testing its filters according to the ISO 16890 standard with the filter test system located in ULPALAB, demonstrating its success with the EUROVENT certification that very few filter manufacturers worldwide possess. - [Ulpatek continues its journey while maintaining its “reliable company” image](https://www.ulpatek.com/lpatek-continues-its-journey-while-maintaining-its-reliable-company-image/): Ulpatek Filter General Manager Ganim Dokuyucu, starting his evaluations by reminding that they have left behind their 40th year in the HVAC sector, emphasized the continued growth of the air filter sector in Turkey with the investments made in 2017. He continued, "With the investments, there has been a significant increase in competition in the sector. This competition naturally puts pressure on especially newly established companies. These companies develop strategies based on low prices to establish themselves in the sector. This situation inevitably leads to a decrease in the quality of raw materials and labor used in the products, resulting in poor quality in the final product. However, Ulpatek continues to maintain its reliable company image in the sector without getting involved in this vicious cycle, without compromising product quality, and by preserving the trustworthy company image with its R&D studies and engineering infrastructure-requiring products and solutions. In our domestic and international sales teams, we offer project-specific, accurate filter and filtration solutions. With this approach, we continue the line and teachings of our company's founding partner, the late Prof. Dr. F. Taner Özkaynak." - [The Target at Ulpatek Filter: Sustainable Growth](https://www.ulpatek.com/the-target-at-ulpatek-filter-sustainable-growth/): Ferhat Gürer, the Export Manager of Ulpatek Filter, shared the company's activities in 2017, impressions about the SODEX Fair, and goals for 2018.Ferhat Gürer, starting his evaluation by mentioning their move to their new factory with 12,650 square meters of closed area in the middle of January 2017, provided the following information: "During the relocation, we made new investments in our production line. While integrating into our new factory in the first half of 2017, we reflected the advantages of our new factory to our sales in the second half of the year. With our manufacturing infrastructure suitable for product groups, our process speeds increased. We had the opportunity to produce in faster and better production conditions. In recent years, we have achieved the growth rates we targeted in our export sales. - [ULPATEK FILTER MEETS STUDENTS AT ITS NEW FACTORY](https://www.ulpatek.com/ulpatek-filter-meets-students-at-its-new-factory/): Ulpatek Filter has been providing technical knowledge and engineering solutions in the fields of filtration and indoor air quality (IAQ) to companies in the pharmaceutical, healthcare, and food sectors since its establishment. - [Ulpatek Filter Takes Its Training Initiative Abroad](https://www.ulpatek.com/ulpatek-filter-takes-its-training-initiative-abroad/): Ulpatek Filter, conducting educational visits with the slogan 'Ulpatek Explains Proper Filtration' to its customers in various locations throughout Turkey, supports its export success by taking its training initiative abroad and providing filtration training to its overseas distributors. - [Novartis chose ULPATEK](https://www.ulpatek.com/novartis-chose-ulpatek/): In the past period, ULPATEK Safe Change Housing units started to be used at Novartis brand's pharmaceutical production facility in St. Petersburg, Russia. - [ULPATEK has moved to its new factory in line with its goals](https://www.ulpatek.com/ulpatek-has-moved-to-its-new-factory-in-line-with-its-goals/): With over 40 years of experience in the HVAC sector and manufacturing in compliance with standards using the most advanced machinery, ULPATEK Filtre has reached this point. In line with its goals, the company has moved to its new factory located at Yassıören Mahallesi Hadımköy Caddesi No: 158, Akpınar Sanayi Bölgesi 34555 Arnavutköy / Istanbul, with a total closed area of ​​12,650 square meters to effectively meet the needs of its customers. - [Ulpatek Filter met with industry stakeholders at the Chemical Filter Seminar](https://www.ulpatek.com/ulpatek-filter-met-with-industry-stakeholders-at-the-chemical-filter-seminar/): Ulpatek Filter, known for its effectiveness and high quality in particle filtration, also emphasizes awareness in gas phase filtration in both domestic and international markets. - [Ulpatek Team Explaining Proper Filtration](https://www.ulpatek.com/ulpatek-team-explaining-proper-filtration/): Ulpatek Filter has been providing engineering solutions by transferring technical knowledge in filtration and indoor air quality (IAQ) to companies in the pharmaceutical, healthcare, and food sectors through its comprehensive resources and infrastructure since its establishment. - [TTMD, “Particle Filtration in Hygienic Areas” Seminar](https://www.ulpatek.com/ttmd-particle-filtration-in-hygienic-areas-seminar/): The "Particle Filtration in Hygienic Areas" Seminar, organized by the Turkish Society of HVAC Engineers Kocaeli Branch, took place on December 9, 2016, Friday at the Chamber of Mechanical Engineers. The presentations were conducted by ULPATEK Filter Sales Coordinator Ganim Dokuyucu and ULPADUST Company Sales Coordinator Tuna Yeşilırmak. - [The brand opening up to the world, ULPATEK FILTER](https://www.ulpatek.com/the-brand-opening-up-to-the-world-ulpatek-filter/): As the world's population rapidly increases, industrialization and urbanization, causing environmental issues, are growing rapidly, leading to an increase in biological and chemical particles. Breathing healthy air in our living spaces is becoming increasingly difficult. In today's world where the air we breathe poses a significant threat to human health, the importance of conscious filtration is increasing. - [ARTA SANAT GATA is the Exclusive Representative of ULPATEK Filters in the Iranian Market](https://www.ulpatek.com/arta-sanat-gata-is-the-exclusive-representative-of-ulpatek-filters-in-the-iranian-market/): We are pleased to announce that ARTA SANAT GATA is the exclusive representative of ULPATEK filters in the Iranian market. - [ULPATEK Filter Achieved Its 2015 Goals](https://www.ulpatek.com/ulpatek-filter-achieved-its-2015-goals/): The pioneering organization in the filter sector, ULPATEK Filter, evaluated its 2015 activities at the annual ordinary Board of Directors Meeting. The company, which successfully achieved its targeted growth rates and R&D studies, made a name for itself in the sector with campaigns initiated throughout the year. The prominent works of the company in 2015 were as follows: - [ULPATEK attended the MCE 2016 Fair to increase its success in exports!](https://www.ulpatek.com/ulpatek-attended-the-mce-2016-fair-to-increase-its-success-in-exports/): ULPATEK participated in the Mostra Convegno Expocomfort 2016 Fair and, along with its existing foreign business partners, established warm dialogues with many new companies to discuss its product quality and future goals. As always, at this fair, the HEPA Filter product family, Fan Filter Units, and Filter Boxes garnered the most attention. Additionally, the "Safe Change Housing" (BIBO), showcased for the first time at an international fair, received great admiration from visitors. - [ULPATEK successfully completed the ISK-SODEX 2016 Exhibition.](https://www.ulpatek.com/ulpatek-successfully-completed-the-isk-sodex-2016-exhibition/): ULPATEK Filter successfully completed the ISK-SODEX Exhibition held between May 4th and 7th, 2016. The company hosted domestic and international visitors at the fair, providing them with information about their upcoming projects. - [Iceland became the 50th country where Ulpatek Filter has exported its products](https://www.ulpatek.com/iceland-became-the-50th-country-where-ulpatek-filter-has-exported-its-products/): Under the leadership of Prof. Dr. Taner Özkaynak, Ulpatek Filter, which started production, reached 50 countries with its exports to Iceland last week. The air filters produced by Ulpatek Filter are preferred in 50 countries, from America to Russia, from Kenya to Iceland! - [Ulpatek introduced its new filters at the Cleanroom Fair!](https://www.ulpatek.com/ulpatek-introduced-its-new-filters-at-the-cleanroom-fair/): Ulpatek Filter continues to provide engineering solutions by sharing its knowledge and experience in clean air and filtration with companies in the pharmaceutical, healthcare, and food sectors since its establishment. - [Ulpatek took its place at ISH Frankfurt!](https://www.ulpatek.com/ulpatek-took-its-place-at-ish-frankfurt/): Since its establishment, Ulpatek has been participating in the ISH Frankfurt Fair and continued this tradition this year. - [ULPATEK will participate in the Cleanroom Fair](https://www.ulpatek.com/ulpatek-will-participate-in-the-cleanroom-fair/): The Cleanroom Technology, Maintenance, and Equipment Fair will be held on April 16-18, 2015, at the ICEC - Lütfi Kırdar International Convention and Exhibition Center. - [ULPATEK Filter Renovated Its Website](https://www.ulpatek.com/ulpatek-filter-renovated-its-website/): Since its establishment, Ulpatek has been providing its customers with the most suitable solutions through its R&D studies and the filters and units it produces. In order to offer faster and higher quality service to its domestic and international customers, Ulpatek has revamped its website. - [Ulpatek Filter Sales Manager Ganim Dokuyucu answered Daily Show newspaper’s questions](https://www.ulpatek.com/ulpatek-filter-sales-manager-ganim-dokuyucu-answered-daily-show-newspapers-questions/): Before discussing ULPATEK, it is necessary to briefly mention Tetisan Industrial. Founded in 1978, Tetisan is a company with 37 years of history. In its early years, it primarily focused on mechanical installation contracts. Later, in the 1990s, in conjunction with developments in the Turkish textile sector, Tetisan began providing and installing predominantly industrial type air conditioning and ventilation products to companies operating in the textile sector. We constructed facilities for leading companies in the sector such as Akın Tekstil, Edip İplik, Bahariye Mensucat, Ozcanlar Tekstil, and Boyteks. During this period, Tetisan, under the leadership of Prof. Dr. F. Taner Özkaynak, began implementing hygienic air conditioning systems primarily in pharmaceutical factories. We also started manufacturing air handling units used in hygienic air conditioning systems during this time. Tetisan successfully implemented these systems and continues to do so in many pharmaceutical factories such as Roche, Novartis, Sandoz, Pfizer, Abdi İbrahim, Mustafa Nevzat, Deva, and Sanovel İlac. Additionally, Tetisan successfully installed hygienic air conditioning systems at Danone in Lüleburgaz and Pınar Et facilities in İzmir Kemalpaşa. In the early 2000s, we accelerated the production of hospital air conditioning equipment such as air handling units compliant with DIN 1946/4 standards, laminar flow units, HEPA filter housings, and intake grilles. We produced Turkey's first compact operating theater hygienic air conditioning unit (HYG-30) with support from TUBİTAK and TTGV. In the past, Tetisan used filters from a European brand whose ownership changed several times. Each change also changed how the brand was represented in Turkey, which caused confusion in the domestic market and problems with quality and delivery times. In 2005, Tetisan transferred the production rights (know-how) for air conditioning units to Airfel A.Ş. Parallel to these developments, ULPATEK Filtre was established in 2007 under the leadership of Prof. Dr. F. Taner Özkaynak, with contributions from U.Tamer Özkaynak, Recep Ekinci, and Ganim Dokuyucu. Our company has developed a wide range of products consisting of coarse, fine, EPA, HEPA, and ULPA filters of the highest quality, compliant with EN 779 and EN 1822 standards, capable of meeting the filtration needs of all HVAC systems, from the simplest ventilation systems to clean rooms. We first introduced our products to the market by exhibiting them at a SODEX fair in May 2008. ULPATEK was established to provide high-quality filtration solutions against chemical and biological particles resulting from industrialization and population growth, develop products for this purpose, and play a role in solving this global problem. - [ISK-SODEX Istanbul 2014 hosted many domestic and foreign guests](https://www.ulpatek.com/isk-sodex-istanbul-2014-hosted-many-domestic-and-foreign-guests/): Since its establishment, ULPATEK has been attending all ISK-Sodex Istanbul fairs without fail, and this year, it continued this tradition by welcoming its domestic and foreign guests at its usual location. - [ULPATEK received the Eurovent Certification.](https://www.ulpatek.com/ulpatek-received-the-eurovent-certification/): Ulpatek, in March, received the EUROVENT certification, which covers M5, M6, F7, F8, F9 filter classes defined in the EN779:2012 standard, a certification that only a few filter manufacturers in the world possess. ## Pages - [Document library](https://www.ulpatek.com/document-library/): Current Ulpatek documents in one place: the product catalogue, product PDFs, the cleanroom equipment catalogue and our certificates. Search by product name or filter by product group and document language. - [Privacy Policy](https://www.ulpatek.com/privacy-policy/): Last updated: 19 October 2026 - [Cleanroom Equipment Catalogue](https://www.ulpatek.com/cleanroom-equipment-catalogue/): You can request the downloadable PDF version from our sales representative by sending an email to info@ulpatek.com or by calling us at +90 212 623-03-00. - [ULPADUST CATALOGUE](https://www.ulpatek.com/ulpadust-catalogue/): Download the ULPADUST catalogue (PDF, 3.2 MB) - [PRODUCT CATALOGUE](https://www.ulpatek.com/product-catalogue/): Browse the catalogue below or download it as a PDF (October 2026 edition, about 39 MB). For printed copies, email info@ulpatek.com or call +90 212 623-03-00. - [Comparison of Filter Standards: ISO 16890, EN 779 and MERV](https://www.ulpatek.com/filter-technology/comparison-of-filter-standards/): ISO 16890 is the current international standard for air filters used in general ventilation. It replaced EN 779:2012, which was withdrawn across Europe on 30 June 2018. There is no exact one-to-one conversion between the two: an F7 filter is not "equal to" one specific ISO 16890 class, only to a range of possible classes. ISO 16890 classifies a filter by how much of the airborne particulate matter it removes – ePM1, ePM2.5, ePM10 or ISO Coarse – instead of by efficiency at a single 0.4 µm particle size. MERV (ANSI/ASHRAE 52.2) remains a separate North American system and also has no exact equivalence with either. - [ISO 16890](https://www.ulpatek.com/filter-technology/ulpalab-filter-test-labs-2/5686-2/): ISO 16890 standard is the new standard that has replaced the EN779: 2012. This standard covers Coarse filters (Class G), Medium filters (Class M) and Fine filters (Class F) and eliminate the insufficient points of the old standard. With this change in standard, filter users will be able to choose the filter much more accurate according to their needs. ISO 16890 standard considers for the particle size (Particulate Matter = PM) between 0.3 μm and 10 μm for efficiency evaluation. Filters are divided into 4 groups. ePM1 95% ePM1 90% ePM1 85% ePM1 80% ePM1 75% ePM1 70% ePM1 65% ePM1 60% ePM1 55% ePM1 50% Requirement ≥50% Initial Efficiency ≥50% Discharged Efficiency ePM2.5 95% ePM2.5 90% ePM2.5 85% ePM2.5 80% ePM2.5 75% ePM2.5 70% ePM2.5 65% ePM2.5 60% ePM2.5 55% ePM2.5 50% Requirement ≥50% Initial Efficiency ≥50% Discharged Efficiency ePM10 95% ePM10 90% ePM10 85% ePM10 80% ePM10 75% ePM10 70% ePM10 65% ePM10 60% ePM10 55% ePM10 50% Requirement ≥50% Initial Efficiency No discharge requirement ISO Coarse 95% ISO Coarse 90% ISO Coarse 85% ISO Coarse 80% ISO Coarse 75% ISO Coarse 70% ISO Coarse 65% ISO Coarse 60% ISO Coarse 55% ISO Coarse 50% Requirement ePM10 < 50% Initial gravimetric arrestance (Am) No discharge requirement Test procedure of the ISO 16890 standard begins with measuring the efficiency of an air filter at a particle size range of 0.3 μm to 10 μm.The Filter is subjected to an isopropanol vapor atmosphere to eliminate efficiency of electrostatic mechanism.Isopropanol vapor atmosphere conditioned Filter tested again to measure the minimum efficiency ePM1,min and ePM2,5,minEfficiency for each PM size is calculated by the mean of both conditioned and the conditioned filter.The efficiencies for ePM1 are calculated for the particle size 0.3 -1 μm , ePM2.5 for the particle size range of up to 2.5 and ePM10 for the particle size range of up to 10 microns.Calculated efficiency values are rounded to the nearest lower value according to the efficiency values in the ISO 16890 classification groups.For example; According to the test result, the F8 class V-Compact Filter is classified as “ISO ePM1 70%”. This means that the filter separates 70% of PM1 particles. The “e” stands for efficiency in combinition with the particulate matter (PM).Efficiency is given according to PM10, PM2.5 and PM1. The dust holding capacity is calculated for ISO A2/AC Fine synthetic test powder. Initial gravimetric arrestance efficiency is calculated. The filter differential pressure drop (Δp) is measured at the nominal air flow rate. For efficiency evaluation, the particle size is between 0.3-10 μm. The efficiency is measured separately according to the particle range. The efficiency measurement is repeated 24 hours after the IPA process. The «ePMx efficiency» is calculated with the measured efficiencies. The filter performance is determined according to PM10, PM2.5 and PM1. Separately efficiency results in each particle channel. The process is considered when selecting the filter. Global (ISO, International Organization for Standardization). - [ULPALAB Filter Test Labs](https://www.ulpatek.com/filter-technology/ulpalab-filter-test-labs-2/): Efficient air filters (EPA), high efficiency air filters (HEPA) and ultra low penetration air filters (ULPA) are classified and tested according to EN 1822 standard for ventilation and air conditioning systems such as cleanroom applications. - [EN 1822](https://www.ulpatek.com/filter-technology/ulpalab-filter-test-labs-2/en-1822/): Efficiency Particulate Air Filters (EPA), High Efficiency Particulate Air Filters (HEPA) and Ultra Low Penetration Air Filters (ULPA) classified and tested according to EN 1822 standards. These filters are used in many industries including, pharmaceutical manufacturing, Bio-Tech,Electronics, Aerospace, Hospitals, and more. There are independent tests for EPA / HEPA / ULPA class filter and filter media according to EN 1822. 1. Efficiency test of the filter fiber: An efficiency test performed by the filter material manufacturers at the nominal speed and MPPS. 2. Filter leak test: It is the test done at MPPS by using particle counters. An alternative to this test is the oil smoke leakage test for H13 and H14 class filters. 3. Filter efficiency test at MPPS: A method of measurement by scanning the filter surface under test conditions. Efficiency is measured with the particle counters used in this test. MPPS: Most Penetrating Particle Size - [GAS PHASE FILTRATION](https://www.ulpatek.com/filter-technology/gas-phase-filtration/): The EN 779 standard will be canceled completely mid of 2018, and ISO 16890 will be used as a new standard for Air Filter. The main change in standard allows the user to make the filter choice much more precise according to the needs of the users. Ulpatek Filtration has taken pioneering steps to inform the sector about its ISO 16890 standard by giving its brokers and business partners priority to Turkish and English information brochures.Airborne pollution sources are various which can be from natural sources like volcanos, thermal sources, pollens, sand storms and from industrial life like factories, automobile emissions, jet fuels, garbage dumps etc. - [Applications](https://www.ulpatek.com/applications/): It is very important that the HEPA/ULPA filters should be leakproof, have enough filtration area and used in nominal capacities in the pharmaceutical industry where the standards and regulations are very strict. - [EN ISO 14644-1](https://www.ulpatek.com/filter-technology/en-iso-14644-1/): ISO 14644-1 defines the classification of air cleanliness in cleanrooms and associated controlled environments exclusively - [Chemical Filtration](https://www.ulpatek.com/filter-technology/chemical-filtration/): Gas phase filtration and particulate filtration work together for acceptable indoor air quality in controlled environments. Gas pollutants are filtered with Ulpatek's gas phase air filters which are produced from one or mix filter media. Particulate pollutants are controlled with particulate filters which are mentioned in related standards ascourse, fine and absolute filters. Gas phase filter media (pellets) generally are produced using carbon, zeolite, alumina or coconut-based media. Gas phase filtration occurs with the two different methods which are physical and chemical.Process control systems, data centers and other rooms that have instrumentation which has to be environmental controlled must supply G1 classification according to ISA requirements. Achieving room ventilation design requirement must supply a minimum room pressurization of 1-3 air changes per hour and recirculation of 6-12 air changes per hour. Temperature is typically 22 °C (±2 °C) with humidity lower than 50% relative humidity. Tightness of the room is also another parameter while defining the design parameters. In addition to Petrochemical Refinery these parameters, hazardous pollutants are main parameter which must be removed from the enclosed space. Contamination concentration levels are defined in ANSI/ISA-71.04. - [Mechanism of Air Filter](https://www.ulpatek.com/filter-technology/mechanism-of-air-filter/): Filters have different effects that help to catch dust. These; - [Effect Of Measuring Method](https://www.ulpatek.com/filter-technology/effect-of-measuring-method/): Work done under the sponsorship of ASHRAE and private organizations such as filter manufacturers showed that the percentage distribution of particle sizes in the atmosphere depended significantly on the method of measurement. Figure attached shows the relationship between particle size distribution and measurement. For instance, particles smaller than 1.0 micron comprise only 3% by weight of all atmospheric dust particles, but make up 98.5% by count.On the other hand, atmospheric dust particles in the 5.0 to 10 micron size range comprise 52% by weight, but only 0.175% on a count basis. Note that almost all the particles in the atmosphere are less than 1 micron in diameter. - [The Air We Breathe](https://www.ulpatek.com/filter-technology/the-air-we-breathe/): Air is a mixture of gases composed of approximately 21% oxygen, 78% nitrogen, 1% argon, and traces of other gases. The air we breathe also includes particulate material and gases generated by nature, by man, and by industrial processes as seen in the Figure. We are concerned with the particulate matter and gases which influence our health or comfort, which damage the spaces we occupy, or which effect the products or components we are manufacturing. - [News](https://www.ulpatek.com/news/) - [Pharma](https://www.ulpatek.com/applications/pharma/): It is very important that the HEPA/ULPA filters should be leakproof, have enough filtration area and used in nominal capacities in the pharmaceutical industry where the standards and regulations are very strict. - [Industrial](https://www.ulpatek.com/applications/industrial/): Ulpatek offers filters, equipments, and systems solutions for many industries, including pharmaceutical factories, hospitals, food production facilities, commercial buildings and power plants. From oil mist eliminators and dust collectors to gas adsorption filters for corrosive gases and complete process filtration systems, our solutions in this segment are designed around the exact needs of modern manufacturing and industrial processes - ensuring the protection of human health, the environment and equipment. While our filters and systems increase the quality of the products in the process, also protecting the health of people and other living things, the environment and the equipment.The most important issue in industrial applications is corrosion control. Control rooms with electronic equipment, data centers and similar control areas must comply with G1 class according to ISA requirements. The room ventilation design is made according to the air change of 1-3 hours per hour for positive pressurization and 6-12 hours per hour for air circulation. The temperature design is 22 °C (± 2 °C) and the relative humidity is less than 50%. Another parameter that influences design criteria is the leakproofing of the room. One another main parameter that must be removed from enclosed spaces is hazardous gas pollutants.Odors are mainly source by the industrial fields such as biogas, wastewater treatment facilities. Toxic gas cleaning units are generally used for the filtration of dichlor (Cl2), sulfur dioxide (SO2) or ammonia (NH3) gases. - [Commercial Buildings](https://www.ulpatek.com/applications/commercial-buildings/): People spent most of their time (average 90%) in enclosed spaces. This is why commercial buildings are utilising air conditioning filtration systems to improve the comfort of occupants, and ensuring the highest level of indoor air quality to avoid sick building syndrome (particularly in the workplace) is a primary concern for building owners and operators. In closed areas, fine and ultra-fine contaminant particles from external sources of emission (external air, windows, leaks, etc.) and internal emission sources (cigarettes, cooking and vacuum systems, etc.) are defined as factors that increase health risk. The level of pollution in enclosed areas is typically two to five (but can be up to 100) times higher than the level of pollutants found externally.There are basically three issues when designing climate systems to reduce these harmful pollutants and to provide the fresh air required for humans (34 m³ / h (20 CFM) outside air requirement - ASHRAE 62-89). - [Power Plants](https://www.ulpatek.com/applications/power-plants/): The energy needs of developing countries are increasing day by day. It is possible to meet the increasing energy demands by investing in new gas turbine power plants. Filtration is at the head of the most basic requirements for the operation of high-performance, long-life and efficient plants. Dust and particles on gas turbine blades can damage these equipment’s and cause their efficiency to decrease or even to fail over time. To prevent this, correct air filter stages and filter models should be installed in order to provide the desired efficiency of the air inlets of gas turbines.Also, increasing the quality of the air entering the gas turbines is an important factor for the effective use of power plants. In this way, there will be more efficient combustion and energy saving. After all the process, the exhausted air should be also filtered. With the right filtration, the shelf life of the equipment will be more longer and the working efficiency is increasing. - [Food & Beverage](https://www.ulpatek.com/applications/food-beverage/): Ulpatek filters and systems equipments are used in national and international beverage and food production facilities. It is very important to use the appropriate filter stages, filter classes, filter numbers to keep the air quality at the desired level in such a high standard requirements. - [Hospitals](https://www.ulpatek.com/applications/hospitals/): It is very important to correctly design the operating room and intensive care units described in DIN 1946/4 and other relevant standards and to choose the right filtration system. In addition to this, choosing the correct filters for air handling units for a hospital and having indoor air quality in hospitals is essential for the health of your patients, employees and visitors. - [Filter Technology](https://www.ulpatek.com/filter-technology/): Search All Tags EN 1822 Standard Energy Efficiency FAQ Filter Design Filter Efficiency Filter Media Filter Performance Filter Selection Filtration Standards Filtration Technology HEPA Filters ISO 16890 Standard ISO 29463 Standard ULPALAB Sort xSort by titleSort by publication date - [Products](https://www.ulpatek.com/products/): Industrial Dust Collection Systems are generally used for cleaner and safer working environments. Also, energy savings, production efficiency increases, product recoveries, air pollution controls which are other benefits. - [About](https://www.ulpatek.com/about-ulpatek/): Since its inception, Ulpatek has consistently delivered quality and innovation, setting reference points in the air filtration sector. With our extensive industry knowledge, advanced manufacturing facilities, and commitment to quality, we have paved our way to becoming a trusted name in over 80 countries worldwide. Our continuous dedication to research & development and engineering infrastructure ensures that our products meet global standards. It's not just about selling products; at Ulpatek, we offer solutions. Dive into our catalogue to discover the products that make us a preferred brand across borders.ULPATEK, with its roots in hygienic ventilation expertise, has today transformed into a global frontrunner in air filtration; representing innovation, quality, and unwavering trust.Welcome to Ulpatek's latest manufacturing center, where advanced technology meets sustainability. Designed with precision and environmental consciousness in mind, this facility ensures top-quality production while prioritizing safety and efficiency.At Ulpatek, our dedication to superiority is without limits. With our products and services reaching over 80 countries worldwide, we are proud to have a truly global footprint. Our wide reach shows trust in our brand and showcases our dedication to meeting diverse demands and adapting to varied market nuances. - [Contact](https://www.ulpatek.com/contact/): Contact Us Address Address: Yassıören Mahallesi Hadımköy Caddesi No: 158, Akpınar Sanayi Bölgesi, 34555 Arnavutkoy / Istanbul / TURKEY Phone: +90 212 623 0300 Fax: +90 212 623 0303 E-mail: info@ulpatek.com Contact Form Name E-mail Phone Subject Message This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply. I have read the Privacy Policy. Visit 360 Showroom! - [Home Page](https://www.ulpatek.com/): Products ## Services - [RETURN AIR GRILLE](https://www.ulpatek.com/products/system-equipments/return-air-grille/): Return air grilles are specifically engineered for the efficient collection and, when necessary, filtration of return air. These grilles are mounted at the lower parts of side panels within controlled environments. They can be produced with or without filters, according to needs. The system consists of a suction box, grille housing, and return air grille. The grille cover features ball joints and spring-loaded filter clamps, allowing for easy removal and reattachment from within the space. - [FILTER MEDIA TEST SYSTEM – FMT 102](https://www.ulpatek.com/products/articles/filter-media-test-system-fmt-102/): Used measuring the raw material’s filtration efficiency and initial pressure drop values at diffirent air velocities. - [PERFORMANCE TEST SYSTEM – PTS 5002](https://www.ulpatek.com/products/articles/performance-test-system-pts-5002/): Used performance measurements for different model and different efficiency of filters. • The pre-tests of the new designs are carried out after than the design giving the best results replaces the standard product. • Comparison tests of filters which has the same efficiency but made from different raw materials. • Air flow and pressure drop graphs are prepared by measuring the initial pressure drop values of the filter at different rated air flow. - [HEPA / ULPA FILTER TEST SYSTEMS](https://www.ulpatek.com/products/articles/hepa-ulpa-filter-test-systems/): CEN standards in Europe, IEST and MIL standards in the US are used for HEPA and ULPA filters. At Ulpatek, every HEPA and ULPA filter is tested individually in ULPALAB and supplied with its own test certificate.The filter surface is scanned at nominal air flow with an automatic probe connected to particle counters that count particles at the MPPS. • The particle counters measure the aerosol concentration upstream and downstream of the filter during the test. • It is a test method in which the highest penetration value permitted for the filter class is checked in an ISO Class 5 clean zone (ISO 14644-1; formerly Class 100). If there is a leak, it detects the leakage points and print as a figure. • The MPPS scan test is the reference leak test method for HEPA and ULPA filters in EN 1822-1 and ISO 29463-4.Test operator scans the filter surface with the probe which is connected to photometer to check the leakage at 0.3 μm particle size. Test is applied for each filter individually. • In the leak tests of HEPA filters performed at the nominal air flow rate, PAO (Emery 3004) aerosol is used in accordance with EN 1822 / ISO 29463. • The high concentration of aerosol fed during the test is checked in the ISO Class 5 (formerly Class 100) test area by scanning the filter surface and sealing surface with the probe to check leakage. • If there is leakage, repairing can be carried out by applying special adhesive according to the standard and customer requirements to the leakage point. • After installation of the filters in the field, performing this test is recommended before commissioning system.Oil Thread Leak Test is done by naked eye for checking leakage on the HEPA filter surface at a nominal air flow rate using DEHS as aerosol. • The particles formed as oil smoke lines from their leak points can be easily seen with the black colored cabin interior design and the appropriate light angle. • If there is leakage, repairing can be carried out by applying special adhesive according to the standard and customer requirements to the leakage point. • Used as an alternative leak test method for class H13 and H14 class filters. • It provides easy testing for filters which are not suitable for the scanning test (V-Compact, cylinder filter, filters without faceguard protection). - [EN 779:2012 CLASSIFICATION SYSTEM](https://www.ulpatek.com/products/articles/en-7792002-classification-system/): The EN 779:2002 classification system (comprising groups F and G filters) has been changed to three groups (F-,M- and G-filters). - [HEPA FILTER UPGRADE IN AIR HANDLING UNITS, THINGS TO PAY ATTENTION](https://www.ulpatek.com/products/articles/hepa-filter-upgrade-in-air-handling-units-things-to-pay-attention/): Recently, after the new type of coronavirus epidemic, we are getting questions about installing HEPA filters in air handling units of commercial and public buildings such as offices, schools, shopping centers, sports facilities. The guide published by REHVA (REHVA COVID-19 guidance document, 17 March 2020) contains explanations about this issue. However, those who want to take precautions by using HEPA filters in the air handling unit should consider the following points.1-It is important to be aware that the air handling units used in comfort applications are not suitable for hygienic application and the filter mounting frames inside unit are not suitable for HEPA filter. It will not be possible to provide 100% sealing between the HEPA Filter and the mounting frame. Leakage from these points will be seen in validation tests, the efficiency expected from the HEPA filter will not be achieved due to leaks.2-The differential pressure of HEPA filters are very high compared to filters (F7, F9 or PM1) in the last stage of AHU’s in comfort applications. In order to operate in the same air flows, it will be necessary to use much more filtration area in HEPA filters compared to standard AHU filters. However, this is not possible with Rigid or V-Compact models.3-If the HEPA filter will be used without reducing the air flow of the AHU, revision should be made in the filter cell. This revision can be done with changing the mounting frame of AHU or with an additional of filter cabinet.4-Revision in the filter cell will not be enough alone. Fan capacity and system pressure losses should be checked. Otherwise, it is not possible to operate the AHU at the desired air flows. - [CAN HEPA FILTER CAPTURE THE CORONAVIRUS?](https://www.ulpatek.com/products/articles/can-hepa-filter-capture-the-coronavirus/): Regarding the Coronavirus (COVID-19) epidemic, the most common question asked about filtration is that “Can HEPA Filter capture the viruses?” The answer to the question; Yes, HEPA Filters captures the viruses within their efficiency value. - [HEPA Filters](https://www.ulpatek.com/products/articles/hepa-filters/): Prof. Dr. F. Taner Özkaynak - [Secure and Seal: Fan Filter Units in Leak-Proof Design](https://www.ulpatek.com/products/articles/secure-and-seal-fan-filter-units-in-leak-proof-design/): Fan Filter Units are ensuring a leak-proof design that offers superior performance and durability. Please review the detailed profile drawing for a comprehensive understanding of the filter frame's dimensions and design features. This will assist in choosing the perfect filter for your specific requirements. - [Terminal HEPA Filters: Frame Profiles](https://www.ulpatek.com/products/articles/secure-and-seal-hepa-terminal-hood-filters-in-leak-proof-design/): The detailed profile drawing below shows the frame dimensions and design features of Ulpatek terminal HEPA filters. Use it to choose the filter that suits your specific requirements. - [Secure and Seal: Gel Type HEPA Ceiling Filters Units in Leak-Proof Design](https://www.ulpatek.com/products/articles/secure-and-seal-gel-type-hepa-ceiling-filters-units-in-leak-proof-design/): Gel Type HEPA Ceiling Filters are ensuring a leak-proof design that offers superior performance and durability. Please review the detailed profile drawing for a comprehensive understanding of the filter frame's dimensions and design features. This will assist in choosing the perfect filter for your specific requirements. - [Secure and Seal: HEPA Ceiling Filters in Leak-Proof Aluminum Frames](https://www.ulpatek.com/products/articles/secure-and-seal-hepa-ceiling-filters-in-leak-proof-aluminum-frames/): HEPA Ceiling Filters ensure a leak-proof design that offers superior performance and durability. Please review the detailed profile drawing for a comprehensive understanding of the filter frame's dimensions and design features. This will assist in choosing the perfect filter for your specific requirements.*The technical drawings above represent standard Ulpatek aluminium profiles. Special aluminium profile designs can be manufactured based on customer requests, and aluminum profiles with varying depths can be produced. Both mold costs and production times may vary. Please discuss this matter with your sales representative. - [GAS PHASE FILTRATION](https://www.ulpatek.com/products/articles/gas-phase-filtration-2/): Airborne pollution sources are various which can be from natural sources like volcanos, thermal sources, pollens, sand storms and from industrial life like factories, automobile emissions, jet fuels, garbage dumps ete. Pollutants are divided in to three physical conditions as solids, liquids and gases. Effective pollution control can be easily made by particulate and gas phase filtration. These filtration methods and applications are define at ISO16890, EN1822, ISO 10121-3. Airborne pollutants comparison chart shows size differences related particulate and gas phase filtration.In order to apply the control methods for the gas phase pollutants, we have to know the pollutants and it's effects. Main airborne pollution effects;Process control systems, data centers and other rooms that have instrumentation which has to be environmental controlled must supply G1 classification according to ISA requirements. Achieving room ventilation design requirement must supply a minimum room pressurization of 1-3 air changes per hour and recirculation of 6-12 air changes per hour. Temperature is typically 22 °C (±2 °C) with humidity lower than 50% relative humidity. Tightness of the room is also another parameter while defining the design parameters. In addition to these parameters, hazardous pollutants are main parameter which must be removed from the enclosed space. Contamination concentration levels are defined in ANSI/ISA-71.04.Monitoring for gas phase air filters is made by passive monitoring or online monitoring. - [Top Questions On Your Mind](https://www.ulpatek.com/products/articles/top-questions-on-your-mind/): HEPA filters are designed for single use. However, there are some specially laminated HEPA filters that can be cleaned with pressurized air systems like Jet-Pulse. Aside from these, conventional HEPA filters commonly in use cannot be cleaned.The gasket type for HEPA filters shouldn't be assessed independently. The sealing surface of the housing where the HEPA filter will be installed must be fully compatible with the gasket. For instance, gel-type filters are suitable for knife-edge sealing surfaces, while PU foam or EPDM is appropriate for flat surfaces. For surfaces with a test groove, either gel or flat EPDM gasketed HEPA filters should be used. Having the filter and housing manufactured by the same producer reduces potential leakage risks.Where contaminant concentrations are not high, Ulpatek recommends a total life of up to 10 years for HEPA filters, including shelf life; for MDF-framed filters, see question 10. We've observed some Ulpatek HEPA filters in the market still functioning without issues within this period. Factors influencing the filter's service life include: the volume of outdoor and re-circulated air filtered, frequency and duration of aerosol challenge exposure, total amount of aerosol impingement on the filter, method of aerosol introduction to the system, and the efficiency of pre-filtration.For energy efficiency, the advised end-of-life differential pressure value for HEPA and ULPA filters is twice the initial pressure of the filter. Depending on the end user, this value can range between 300-600Pa.Ulpatek recommends a shelf life of up to 3 years. For filters stored beyond this period, a risk analysis should be performed before use. In any case, filters should be stored in their original packaging in a cool and dry environment away from extreme temperature and humidity conditions.Filters can be repaired to specific limits both at the factory and in the field. Recommendations for repair in the factory can be found in the following standards: IEST RP-CC001.5 IEST RP-CC034.4 ISO 29463 Additionally, ISO 14644-3 allows the customer and supplier to mutually agree upon the allowable repair size.According to ISO 29463, ULPA filters (group U, from ISO 50 U upwards) are tested individually: their efficiency is determined at the MPPS in accordance with ISO 29463-5, and they must be leak tested with the MPPS scan method of ISO 29463-4; no alternative leak test is allowed for this group. (EN 1822 class U15 corresponds to ISO 55 U.)EN 1822, ISO 29463, IEST-RP-CC001 and IEST-RP-CC034 are international standards related to air filtration, specifically focusing on high-efficiency particulate air (HEPA) and ultra-low penetration air (ULPA) filters. These standards define the requirements and test procedures for the classification, performance, and marking of these filters at factory. ISO14644-3:2019 which Portions of the test methods have been adapted from IEST-RP-CC034.4 specifies procedures for the leakage test of installed HEPA filters.Conventional micro glass fiber has a homogeneous structure, and both of its surfaces possess identical properties, there might indeed be no specific airflow direction required for HEPA filters produce by this filtration media. However, when an additional component or surface feature, like lamination, is used the direction of airflow becomes important.HEPA filters with MDF (Medium Density Fiberboard) frames present certain concerns, especially in humid environments. The natural fibrous structure of MDF allows for the absorption of moisture, creating a conducive environment for the growth of microorganisms. Prolonged exposure to humidity can also lead to the formation of micro-cracks in the MDF structure. These cracks can directly impact filter performance, as they may hinder the proper flow of air through the filter or cause leakages. Due to these reasons, the recommended usage duration for MDF-framed HEPA filters is one year. - [EN1822 and ISO29463: HEPA Filter Tests and Standards](https://www.ulpatek.com/products/articles/en1822-and-iso29463-hepa-filter-tests-and-standards/): EN 1822, a European standard, provides a detailed classification system for HEPA and ULPA filters based on their filtration efficiency and ability to capture particles of various sizes. Its test methods (the efficiency test and the leak test, including the scan method) have been defined in EN ISO 29463 Parts 2–5 since 2019. - [Recommendations for Fine Dust Filtration Filters](https://www.ulpatek.com/products/articles/recommendations-for-fine-dust-filtration-filters/): Regular Inspection: Check the filter regularly for visible signs of clogging or damage. A blocked filter can hinder system performance.Final Pressure Drop: According to the EN 13053 standard, the final pressure drop is determined. ISO ePM1, ISO ePM2.5, and ISO ePM10 classes is calculated by either adding 100 Pascal (Pa) to the initial pressure drop of clean filters or by calculating a value up to three times smaller than the initial pressure drop of clean filters. - [Eurovent Certification: Verified Performance](https://www.ulpatek.com/products/articles/eurovent-certification-a-guarantee-of-performance/): At Ulpatek, we take quality and performance seriously. Our air filters are Eurovent certified, which means that their declared performance has been verified by independent laboratory tests. Eurovent certification is a valuable asset for any HVAC system.Why Eurovent?Trust: A globally recognized seal, ensuring our filters meet strict performance standards. - [Basic Principles of Mechanical Filtration](https://www.ulpatek.com/products/articles/basic-principles-of-mechanical-filtration/): It is the simplest filtration mechanism. It is the process of capturing particles larger than the gap between the two fiber threads used as the filter element.Particles, when encountering a filter fiber in their path, want to continue their journey without altering their parallel orientation. However, due to their inertia, they fail to do so and instead collide with the fiber and adhere to its surface.If the particle size is very small, the particle can follow an orbit around the fiber thread along with the air. However, if this orbit passes closer to the fiber than half the particle radius, the particle is captured by the fiber and adheres to it.When the particle size is smaller than 1 µm, gas molecules colliding with the particles can cause them to move erratically. As a result of this behavior, particles colliding with the filter fiber can adhere to the filter.Between charged particles and filter fibers, particles adhere to the fibers due to the principle of opposite charges attracting each other. - [ISO 16890 Standard for Air Filters Used in General Ventilation](https://www.ulpatek.com/products/articles/iso-16890-standard-for-air-filters-used-in-general-ventilation/): ISO 16890 replaced EN 779 as the standard for general ventilation air filters in 2018; in North America, ASHRAE 52.2 (MERV) is still used. ISO 16890 measures the efficiency of an air filter in the particle size range 0.3 μm to 10 μm. The classification is carried out according to standard for particle size range 0.3-1.0 μm, 0.3-2.5 μm and 0.3-10 μm. The process is considered while choosing filters according to more detailed and global standard.A synthetic powder called ASHRAE dust is used in the efficiency test of an air filter according to EN779: 2012 standard. The test is done by loading the filter with this powder in the laboratory environment. By this way, the efficiency of the filter can be calculated in the particle size of only 0.4 μm . In operating conditions, filters are exposed to pollutants with a variety of different sized particulate. Therefore, the data obtained in the laboratory is insufficient to determine the performance of an air filter.The EN 779: 2012 standard which was used in the classification of Coarse filters, Medium Filters and Fine Filters replaced by the ISO 16890 standard. With this change in standard, filter users will are able to choose the filter much more accurate according to their needs.ISO 16890 standard considers for the particle size (Particulate Matter = PM) between 0.3 µm and 10 µm for efficiency evaluation. - [Recommendations for Coarse Filtration Filters](https://www.ulpatek.com/products/articles/recommendations-for-coarse-filtration-filters/): Regular Inspection: Check the filter regularly for visible signs of clogging or damage. A blocked filter can hinder system performance and can be detrimental to subsequent fine filters.Final Pressure Drop: According to the EN 13053 standard, the final pressure drop is determined. ISO Coarse class is calculated by adding 50 Pascal (Pa) to the initial pressure drop of clean filters or by calculating a value up to three times smaller than the initial pressure drop of clean filters. ISO ePM1, ISO ePM2.5, and ISO ePM10 classes is calculated by either adding 100 Pascal (Pa) to the initial pressure drop of clean filters or by calculating a value up to three times smaller than the initial pressure drop of clean filters. - [Selection of Filters According to ISO 16890 Standard in HVAC Applications](https://www.ulpatek.com/products/articles/selection-of-filters-according-to-iso-16890-standard-in-hvac-applications/): ISO 16890 standardizes the selection of air filters and gives it a scientific basis. Selecting air filters based on the ISO 16890 standard is important for improving indoor air quality and the efficiency of HVAC (Heating, Ventilation, and Air Conditioning) systems. Members of the Eurovent Association, which includes filter manufacturers playing a significant role in the Europe, Middle East, and Africa (EMEA) market, have published the document 'Eurovent REC 4/23.' This document provides recommendations for selecting filters to achieve the required indoor air quality according to ISO 16890 standards, drawing upon the work of the World Health Organization (WHO). To achieve the desired indoor air quality, the outdoor air particle concentration values have been categorized based on general ventilation and industrial usage. The required supply air (SUP) quality is obtained through recommended filtration efficiency to attain the desired indoor air quality. - [Particle Matter](https://www.ulpatek.com/products/articles/particle-matter/): Due to increased air pollution, the effects of particulates on human health has begun to be discussed in more detail. The results show that particle matter is a serious health hazard that causes respiratory diseases and cancers. Air filters for general ventilation are widely used in buildings for heating, ventilation and air conditioning applications. Air filters increase the indoor air quality by reducing the particulate matter concentration, thereby protecting human health considerably.Particles larger than 10 μm in the atmosphere collapse very quickly and they can only hang in the air in strong wind near the source they are leaving. As an exception, some light fibers can stay in the air longer, despite their large diameter. Most particles larger than 10 μm in diameter can be seen with the naked eye in case of proper illumination and contrast. Under normal conditions, the minimum visible particle diameter is 30 μm and above.Particles ranging in diameter from 5 to 10 μm or larger are separated and trapped by the upper respiratory tract. The intermediate sizes collaps on air channels of the lungs, then swallowed or coughed. Particles ranging in diameter from 2.5 to 5 μm are likely to be retained in human lungs and are returned to the upper respiratory tract without falling into the depths of the lungs. Particles ranging in diameter from 1 to 2.5 μm are retained in the bronchi and pose risks to human health. The particles at 1 μm and below are small enough to interfere with the blood flow from the cell membranes of the alveoli.HVAC (Heating, Ventilation, and Air Conditioning) systems are fundamental to maintaining a comfortable and healthy indoor environment. However, airborne contaminants, such as particulates and particle matter (PM), can significantly hinder their performance and energy efficiency, emphasizing the need for effective filtration and maintenance. - [Understanding Most Penetrating Particle Size (MPPS)](https://www.ulpatek.com/products/articles/understanding-most-penetrating-particle-size-mpps/): Most Penetrating Particle Size (MPPS) refers to the particle size that is most difficult to capture. The MPPS is important to consider when choosing an air filter, as it is the worst-case scenario for particle removal efficiency. For HEPA filters MPPS is generally between 0.1-0.2 microns. The standard determines efficiency based on this critical value. We can say that particles smaller or larger than MPPS are captured at higher efficiency compared to MPPS efficiency. - [What is HEPA Filter?](https://www.ulpatek.com/products/articles/what-is-hepa-filter/): A High Efficiency Particulate Air (HEPA) filter is a type of air filter designed to remove very fine airborne particles, such as virus, bacteria, and mold spores, from the air. These filters are commonly used in various applications, including pharmaceutical cleanrooms, healthcare facilities, microelectronics, and food & beverage, to improve indoor air quality and protect sensitive equipment or processes. - [The Total Cost of Ownership of Air Filters](https://www.ulpatek.com/products/articles/the-total-cost-of-ownership-of-air-filters/): It is essential to understand the total cost of ownership (TCO) of air filters before making any purchasing decisions. There are various factors affecting TCO, such as, energy cost, filter cost, labor, and disposal, to help you make an informed decision.Energy consumption is one of the most significant contributors to the TCO of an air filter. Higher energy consumption results in higher operating costs. Factor that affect energy consumption is the pressure drop of filter. Pressure drop is the reduction in air pressure as it passes through the filter media. A higher pressure drop means the HVAC system must work harder, increasing energy consumption and operating costs. To minimize TCO, consider filters with a lower pressure drop that allow for optimal airflow and reduced energy usage.The initial purchase price of the air filter is an essential component of TCO. High-efficiency filters may have a higher initial cost, but they often require less frequent replacement and provide better air quality, leading to long-term savings. Consider the overall lifetime value of a filter instead of focusing solely on its initial cost.The labor cost associated with filter replacement and maintenance contributes to the TCO. High-quality filters typically have a longer lifespan, reducing the frequency of replacements and labor costs. When evaluating TCO, consider the cost of hiring technicians and the time required for filter replacements.Disposing of used filters contributes to the TCO as it involves costs for transportation and waste management. Selecting filters with extended lifespans and recyclable materials can help reduce disposal costs and minimize the environmental impact.To calculate the Total Cost of Ownership, it is necessary to first calculate the energy consumption. The energy consumption formula is as follows.Under Other Costs, there are expenses related to storage, transportation, losses due to damage, and waste disposal costs.Understanding the total cost of ownership of air filters is crucial for making informed purchasing decisions. By considering factors such as pressure drop, energy cost, filter cost, labor and disposal, cleaning, you can choose the right filter for your needs while minimizing long-term expenses. Remember that investing in high-quality, energy-efficient filters can lead to significant savings and better indoor air quality in the long run. - [HEPA CYLINDRICAL FILTER](https://www.ulpatek.com/products/absolute-filtration/hepa-cylindrical-filter/): “Any inner, outer and lenght dimensions are available on request.” - [EFFICIENT DUCT TYPE FILTER](https://www.ulpatek.com/products/absolute-filtration/efficient-duct-type-filter/): “Differential Pressure Tolerance ±10%” - [HEPA FILTER WITH ALUMINIUM SEPARATOR (MDF FRAME)](https://www.ulpatek.com/products/absolute-filtration/hepa-filter-with-aluminium-seperator-mdf-frame/): Final filter for hygenic AHU’s Disposable Static electricty granding cable available on request Tested and certified acc to EN 1822 - ISO 29463 for H13 - H14 Corrugated aluminium separator Guaranteed leak-free Filter Class:E10 - E11 - E12 - H13 - H14Flange:Without Media:High quality glass fiberSealing Compound:Two component polyurethane Frame:MDFSeparator:Corrugated Aluminium Rec. Final Pressure Drop: Initial pressure drop x2, (max. 600 Pa)Gasket:EPDM and PU Foam Max. Operating Temperature:80 °C Filter TypeFilter ClassFrameStatic Electricity Grounding CableDimensions (mm)FaceguardGasket HCA : HEPA Filter with Aluminium Separator (MDF Frame)E10 E11 E12 H13 H14M: MDF SG: Exist W: Without610x610x292FW: Without FC: On Clean Side FD: On Dirty Side FB: On Both SidesW: Without P: Continuous Pu Foam PP: Pu Foam on Both Side E: EPDM Flat EE: EPDM Flat on Both Side C: Continuous Grey EPDM CC: Grey EPDM on Both Side Filter ModelEN 1822ISO 29463Dimensions WxHxD (mm)Filtration Area (m²)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) HCA-E10-M-W-305-610-292-FW-EE10-305x610x2928,51700170 HCA-E10-M-W-610-610-292-FW-EE10-610x610x292173400170 HCA-E11-M-W-305-610-292-FW-EE11ISO 15 E305x610x2928,51700190 HCA-E11-M-W-610-610-292-FW-EE11ISO 15 E610x610x292173400190 HCA-E12-M-W-305-610-292-FW-EE12ISO 25 E305x610x2928,51500270 HCA-E12-M-W-610-610-292-FW-EE12ISO 25 E610x610x292173000270 HCA-H13-M-W-305-610-292-FW-EH13ISO 35 H305x610x292111250250 HCA-H13-M-W-610-610-292-FW-EH13ISO 35 H610x610x292222500250 HCA-H14-M-W-305-610-292-FW-EH14ISO 45 H305x610x292111100250 HCA-H14-M-W-610-610-292-FW-EH14ISO 45 H610x610x292222200250 “Other dimensions are available on request.” “Differential Pressure Tolerance ±10%” - [HEPA FILTER WITH ALUMINIUM SEPARATOR (METAL FRAME)](https://www.ulpatek.com/products/absolute-filtration/compact-hepa-filter-with-aluminium-seperator/): Final filter for hygenic AHU’s under high temperature conditions - [EFFICIENT PANEL FILTER](https://www.ulpatek.com/products/absolute-filtration/efficient-panel-filter/): Final filter for HVAC or cleanrooms Tested and certified acc to EN 1822 - ISO 29463 for H13 - H14 Large filtration area Simple and light weight Low initial pressure drop Filter Standard:EN 1822 and ISO 29463Max. Operating Temperature:80 °C Filter Class:E10 - E11 - E12 - H13 - H14Faceguard:Available on request Media:Glass FiberGasket:Available on request Frame:Galvanized, Stainless SteelSealing Compound:Two component polyurethane Rec. Final Pressure Drop:Initial pressure drop x2, (max. 600 Pa)Separators:Hotmelt Filter TypeFilter ClassFrameDimensions (mm)FaceguardGasket HP : Efficient Panel FilterE10 E11 E12 H13 H14G : Galvanized592x592x96FW: Without FC: On Clean Side FD: On Dirty Side FB: On Both SidesW: Without P: Continuous Pu Foam PP: Pu Foam on Both Sides E: EPDM EE: EPDM Flat On Both Sides C: Continuous Grey EPDM CC: Grey EPDM on Both Sides Filter ModelEN 1822ISO 29463Dimensions WxHxD (mm)Filtration Area (m²)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) HP-E10-G-287-287-48-FW-WE10-287x287x481,5300190 HP-E10-G-287-592-48-FW-WE10-287x592x483600190 HP-E10-G-592-592-48-FW-WE10-592x592x4861200190 HP-E11-G-287-287-48-FW-WE11ISO 15 E287x287x481,5250200 HP-E11-G-287-592-48-FW-WE11ISO 15 E287x592x483500200 HP-E11-G-592-592-48-FW-WE11ISO 15 E592x592x4861000200 HP-E12-G-287-287-48-FW-WE12ISO 25 E287x287x481,5130170 HP-E12-G-287-592-48-FW-WE12ISO 25 E287x592x483275170 HP-E12-G-592-592-48-FW-WE12ISO 25 E592x592x486570170 HP-H13- G-287-287-48-FC-PH13ISO 35 H287x287x481,5130180 HP-H13- G-287-592-48-FC-PH13ISO 35 H287x592x483275180 HP-H13- G-592-592-48-FC-PH13ISO 35 H592x592x486570180 HP-H14- G-287-287-48-FC-PH14ISO 45 H287x287x481,5130200 HP-H14- G-287-592-48-FC-PH14ISO 45 H287x592x483275200 HP-H14- G-592-592-48-FC-PH14ISO 45 H592x592x486570200 “Other dimensions are available on request.” “Differential Pressure Tolerance ±10%” Filter ModelEN 1822ISO 29463Dimensions WxHxD (mm)Filtration Area (m²)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) HP-E10-G-287-287-96-FW-WE10-287x287x963600175 HP-E10-G-287-592-96-FW-WE10-287x592x9661200175 HP-E10-G-592-592-96-FW-WE10-592x592x96122400175 HP-E11-G-287-287-96-FW-WE11ISO 15 E287x287x963500150 HP-E11-G-287-592-96-FW-WE11ISO 15 E287x592x9661000150 HP-E11-G-592-592-96-FW-WE11ISO 15 E592x592x96122000150 HP-E12-G-287-287-96-FW-WE12ISO 25 E287x287x96326085 HP-E12-G-287-592-96-FW-WE12ISO 25 E287x592x96655085 HP-E12-G-592-592-96-FW-WE12ISO 25 E592x592x9612114085 HP-H13-G-287-287-96-FC-PH13ISO 35 H287x287x96326085 HP-H13-G-287-592-96-FC-PH13ISO 35 H287x592x96655085 HP-H13-G-592-592-96-FC-PH13ISO 35 H592x592x9612114085 HP-H14-G-287-287-96-FC-PH14ISO 45 H287x287x963260110 HP-H14-G-287-592-96-FC-PH14ISO 45 H287x592x966550110 HP-H14-G-592-592-96-FC-PH14ISO 45 H592x592x96121140110 “Other dimensions are available on request.” “Differential Pressure Tolerance ±10%” - [EFFICIENT RIGID FILTER (PLASTIC FRAME)](https://www.ulpatek.com/products/absolute-filtration/efficient-rigid-filter-plastic-frame/): “Differential Pressure Tolerance ±10%” - [EFFICIENT RIGID FILTER (ALUMINIUM FRAME)](https://www.ulpatek.com/products/absolute-filtration/efficient-rigid-filter-aluminium-frame/): Final filter for HVAC or cleanrooms Tested and certified acc to EN 1822 - ISO 29463 for H13 - H14 Large filtration area Simple and light weight Low initial pressure drop Filter Standard:EN 1822 and ISO 29463Max. Operating Temperature:80 °C Filter Class:E10 - E11 - E12 - H13 - H14Depth:100 and 130 mm Media:Glass FiberFaceguard:Available on request Frame:Anodized, extruded aluminiumSealing Compound: Two component polyurethane Rec. Final Pressure Drop:Initial pressure drop x2, (max. 600 Pa)Separators: Hotmelt Filter TypeFilter ClassFrameFlangeDimensions (mm)Faceguard Gasket HR : Efficient Rigid Filter (Aluminium Frame)E10 E11 E12 H13 H14A : Aluminium20 25592x592x130FW: Without FC: On Clean Side FD: On Dirty Side FB: On Both SidesW: Without E: EPDM EE: EPDM Flat On Both Sides C: Continuous Grey EPDM CC: Grey EPDM on Both Sides Filter ModelEN 1822ISO 29463Dimensions WxHxD (mm)Filtration Area (m²)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) HR-E10-A-25-287-287-130-FW-WE10-287x287x1303,2625190 HR-E10-A-25-287-592-130-FW-WE10-287x592x1306,51250190 HR-E10-A-25-592-592-130-FW-WE10-592x592x130132500190 HR-E11-A-25-287-287-130-FW-WE11ISO 15 E287x287x1303,2500210 HR-E11-A-25-287-592-130-FW-WE11ISO 15 E287x592x1306,51000210 HR-E11-A-25-592-592-130-FW-WE11ISO 15 E592x592x130132000210 HR-E12-A-25-287-287-130-FW-WE12ISO 25 E287x287x1303,2375250 HR-E12-A-25-287-592-130-FW-WE12ISO 25 E287x592x1306,5750250 HR-E12-A-25-592-592-130-FW-WE12ISO 25 E592x592x130131500250 HR-H13-A-25-287-287-130-FC-EH13ISO 35 H287x287x1303,2375270 HR-H13-A-25-287-592-130-FC-EH13ISO 35 H287x592x1306,5750270 HR-H13-A-25-592-592-130-FC-EH13ISO 35 H592x592x130131500270 HR-H14-A-25-287-287-130-FC-EH14ISO 45 H287x287x1303,2300270 HR-H14-A-25-287-592-130-FC-EH14ISO 45 H287x592x1306,5600270 HR-H14-A-25-592-592-130-FC-EH14ISO 45 H592x592x130131200270 “Other dimensions are available on request.” “Differential Pressure Tolerance ±10%” - [EFFICIENT V-COMPACT FILTER (METAL FRAME)](https://www.ulpatek.com/products/absolute-filtration/efficient-v-compact-filter-metal-frame/): “Differential Pressure Tolerance ±10%” - [EFFICIENT V-COMPACT FILTER](https://www.ulpatek.com/products/absolute-filtration/efficient-v-compact-filter/): “Differential Pressure Tolerance ±10%” - [HIGH CAPACITY NUCLEAR FILTER WITH V MODULE DESIGN](https://www.ulpatek.com/products/absolute-filtration/high-capacity-hepa-nuclear-filter/): “Differential Pressure Tolerance ±10%” - [HIGH CAPACITY HEPA FILTER WITH V MODULE DESIGN (PLASTIC FRAME)](https://www.ulpatek.com/products/absolute-filtration/high-capacity-hepa-filter-with-v-module-design-plastic-frame/): Other filter classes in the order code (E10–E12) are available on request. - [HIGH CAPACITY HEPA FILTER WITH V MODULE DESIGN (METAL FRAME)](https://www.ulpatek.com/products/absolute-filtration/high-capacity-hepa-filter-v-modul/): Other filter classes in the order code (E10–E12) are available on request. - [PRO BAG FILTER](https://www.ulpatek.com/products/coarse-filtration/pro-bag-filter/): Pre-filter for ventilation equipment and HVAC Power plants Self supporting pockets No special mechanical support required High dust holding capacity Robust construction Filter Standard:ISO16890Rec. Final Pressure Drop EN13053:Initial ΔP +50 Pa or initial ΔP x3 whichever is lower Filter Class:ISO CoarseMax. Operating Temperature:80 °C Media:Synthetic FiberFrame depth:20 - 25 mm Frame:Galvanized Filter TypeFilter ClassPocket NumberFlangeDimensions (mm) GBP : Pro Bag FilterG3 G4P3 P4 P5 P6 P7 P820, 25592x592x500 Filter ModelEN 779 (cancelled) ISO 16890Dimensions WxHxD (mm)Pocket NumberFiltration Area (m²)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) GBP-G3-P3-25-287-592-360G3Coarse 45%287x592x36031.3170040 GBP-G3-P5-25-490-592-360G3Coarse 45%490x592x36052.1280040 GBP-G3-P6-25-592-592-360G3Coarse 45%592x592x36062.6340040 GBP-G3-P3-25-287-592-500G3Coarse 45%287x592x50031.8170035 GBP-G3-P5-25-490-592-500G3Coarse 45%490x592x50053280035 GBP-G3-P6-25-592-592-500G3Coarse 45%592x592x50063.6340035 GBP-G3-P3-25-287-592-600G3Coarse 45%287x592x60032.1170030 GBP-G3-P5-25-490-592-600G3Coarse 45%490x592x60053.6280030 GBP-G3-P6-25-592-592-600G3Coarse 45%592x592x60064.3340030 GBP-G4-P3-25-287-592-360G4Coarse 55%287x592x36031.3170050 GBP-G4-P5-25-490-592-360G4Coarse 55%490x592x36052.1280050 GBP-G4-P6-25-592-592-360G4Coarse 55%592x592x36062.6340050 GBP-G4-P3-25-287-592-500G4Coarse 55%287x592x50031.8170045 GBP-G4-P5-25-490-592-500G4Coarse 55%490x592x50053280045 GBP-G4-P6-25-592-592-500G4Coarse 55%592x592x50063.6340045 GBP-G4-P3-25-287-592-600G4Coarse 55%287x592x60032.1170040 GBP-G4-P5-25-490-592-600G4Coarse 55%490x592x60053.6280040 GBP-G4-P6-25-592-592-600G4Coarse 55%592x592x60064.3340040 “Other dimensions are available on request.” “Differential Pressure Tolerance ( ±10% + 5 Pa ) or ( 10 Pa + 5 Pa ) whichever is greater” - [HIGH CAPACITY HEPA FILTER WITH SINGLE PLEAT (MDF FRAME)](https://www.ulpatek.com/products/absolute-filtration/high-capacity-hepa-filter-with-single-pleat-mdf-frame/): Other filter classes in the order code (E10–E12, U15) are available on request. - [HIGH CAPACITY HEPA FILTER WITH SINGLE PLEAT (METAL FRAME)](https://www.ulpatek.com/products/absolute-filtration/high-capacity-hepa-filter-with-single-pleat/): Other filter classes in the order code (E10–E12, U15) are available on request. - [CYLINDRICAL FILTER](https://www.ulpatek.com/products/fine-dust-filtration/cylindrical-filters/): “Other dimensions are available on request.” - [ECO BAG FILTER](https://www.ulpatek.com/products/coarse-filtration/bag-filter/): Pre-filter for ventilation equipment and HVAC Highly effective with coarse dust Middle support prevents bypass between filter pockets Filter Standard:ISO16890Rec. Final Pressure Drop EN13053:Initial ΔP +50 Pa or initial ΔP x3 whichever is lower Filter Class:ISO CoarseMax. Operating Temperature:80 °C Media:Synthetic FiberFrame depth:20 - 25 mm Frame:Galvanized Filter TypeFilter ClassPocket NumberFlangeDimensions (mm) GB : Eco Bag FilterG4P3 P4 P5 P6 P7 P8 P9 P1020, 25592x592x500 Filter ModelEN 779 (cancelled) ISO 16890Dimensions WxHxD (mm)Pocket NumberFiltration Area (m²)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) GB-G4-P3-25-287-592-360G4Coarse 55%287x592x36032.4170050 GB-G4-P5-25-490-592-360G4Coarse 55%490x592x36054280050 GB-G4-P6-25-592-592-360G4Coarse 55%592x592x36064.8340050 GB-G4-P3-25-287-592-500G4Coarse 55%287x592x50033.5170045 GB-G4-P5-25-490-592-500G4Coarse 55%490x592x50055.8280045 GB-G4-P6-25-592-592-500G4Coarse 55%592x592x50067340045 GB-G4-P3-25-287-592-600G4Coarse 55%287x592x60034170040 GB-G4-P5-25-490-592-600G4Coarse 55%490x592x60056.7280040 GB-G4-P6-25-592-592-600G4Coarse 55%592x592x60068340040 “Other dimensions are available on request.” “Differential Pressure Tolerance ( ±10% + 5 Pa ) or ( 10 Pa + 5 Pa ) whichever is greater” - [TERMINAL HOOD WITH CHANGEABLE HEPA FILTER (RSR : ROOM SIDE REPLACEMENT)](https://www.ulpatek.com/products/absolute-filtration/terminal-hood-with-changeable-hepa-filter-rsr-room-side-replacement/): Final filter for cleanrooms Life science Microelectronics Self-contained air inlet Self-boxed, need for narrower space Differential pressure (∆P) port and 100% upstream aerosol test port (accessible from technical side) Guaranteed leak-free Individual test certificate (acc. to EN 1822 - ISO 29463) Filter change from the room side Filter Standard:EN 1822 and ISO 29463Max. Operating Temperature:80 °C Filter Class:H13 - H14 - U15Faceguard:Aluminium sheet (powder coated) Media:High quality glass fiberSealing Compound:Two component polyurethane Frame:Anodized extruded aluminiumSeparator:Hotmelt Rec. Final Pressure Drop:Initial pressure drop x2, (max. 600 Pa) Filter TypeFilter ClassDesignDividerDimensions (mm)Spigot DiameterFaceguardGasket HTH : Terminal Hood with Changeable HEPA FilterH13 H14 U15J: Gel typeW: Without D: Exist610x610x175A: 125 B: 150 C: 160 D: 200 M: 250 F: 300 L: 315 X: 355 Z: SpecialFW: Without FC: On Clean Side FD: On Dirty Side FB: On Both SidesG: Gel Filter ModelEN 1822ISO 29463Dimensions WxHxD (mm)Suitable Filter Dimensions (mm)Spigot Diameter (mm)Filter Nominal Airflow (m³/h)Filter Inital Pressure Drop (Pa) HTH-H13-J-W-305-305-175-C-FB-WH13ISO 35 H305x305x175270x270x10416012085 HTH-H13-J-W-305-610-175-D-FB-WH13ISO 35 H305x610x175270x575x10420025085 HTH-H13-J-W-457-457-175-D-FB-WH13ISO 35 H457x457x175422x422x10420029085 HTH-H13-J-W-610-610-175-M-FB-WH13ISO 35 H610x610x175575x575x10425053585 HTH-H13-J-W-610-915-175-M-FB-WH13ISO 35 H610x915x175575x880x10425082085 HTH-H13-J-W-610-1220-175-L-FB-WH13ISO 35 H610x1220x175575x1185x104315110085 HTH-H14-J-W-305-305-175-C-FB-WH14ISO 45 H305x305x175270x270x104160120100 HTH-H14-J-W-305-610-175-D-FB-WH14ISO 45 H305x610x175270x575x104200250100 HTH-H14-J-W-457-457-175-D-FB-WH14ISO 45 H457x457x175422x422x104200290100 HTH-H14-J-W-610-610-175-M-FB-WH14ISO 45 H610x610x175575x575x104250535100 HTH-H14-J-W-610-915-175-M-FB-WH14ISO 45 H610x915x175575x880x104250820100 HTH-H14-J-W-610-1220-175-L-FB-WH14ISO 45 H610x1220x175575x1185x1043151100100 HTH-U15-J-W-305-305-175-C-FB-WU15ISO 55 U305x305x175270x270x104160120115 HTH-U15-J-W-305-610-175-D-FB-WU15ISO 55 U305x610x175270x575x104200250115 HTH-U15-J-W-457-457-175-D-FB-WU15ISO 55 U457x457x175422x422x104200290115 HTH-U15-J-W-610-610-175-M-FB-WU15ISO 55 U610x610x175575x575x104250535115 HTH-U15-J-W-610-915-175-M-FB-WU15ISO 55 U610x915x175575x880x104250820115 HTH-U15-J-W-610-1220-175-L-FB-WU15ISO 55 U610x1220x175575x1185x1043151100115 The filter size is 35 mm smaller than the frame size. “Other dimensions are available on request.” “Differential Pressure Tolerance ±10%” - [PLASTIC FRAME ZIG-ZAG FILTER](https://www.ulpatek.com/products/coarse-filtration/plastic-frame-zig-zag-filter/): Pre-filter for ventilation equipment and HVAC Highly effective with coarse dust Air Intake Systems Simple and light weight Disposable Plastic frame Filter Standard: ISO 16890Rec. Final Pressure Drop EN13053:Initial ΔP +50 Pa or initial ΔP x3 whichever is lower Filter Class: ISO CoarseMax. Operating Temperature:80 °C Media:Synthetic FiberStandard depth:48 - 96 mm Frame:Polystyrene Filter TypeFilter ClassFrameCapacityDimensions (mm)FaceguardGasket GZ-P-H : Plastic Frame Zig-Zag FilterG4P : PlasticH: High592x592x48FW: Without FC: On Clean Side FD: On Dirty Side FB: On Both SidesW: Without P: Continuous Pu Foam PP: Pu Foam on Both Sides E: EPDM EE: EPDM Flat On Both Sides C: Continuous Grey EPDM CC: Grey EPDM on Both Sides Filter ModelEN 779 (cancelled)ISO 16890Dimensions WxHxD (mm)Filtration Area (m²)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) GZ-G4-P-H-287-287-48G4Coarse 65%287x287x480.385080 GZ-G4-P-H-287-592-48G4Coarse 65%287x592x480.6170080 GZ-G4-P-H-592-592-48G4Coarse 65%592x592x481.2340080 GZ-G4-P-H-287-287-96G4Coarse 65%287x287x960.685055 GZ-G4-P-H-287-592-96G4Coarse 65%287x592x961.2170055 GZ-G4-P-H-592-592-96G4Coarse 65%592x592x962.4340055 “Other dimensions are available on request.” “Differential Pressure Tolerance ( ±10% + 5 Pa ) or ( 10 Pa + 5 Pa ) whichever is greater” - [DUCT TYPE FINE DUST FILTER](https://www.ulpatek.com/products/fine-dust-filtration/duct-type-fine-dust-filter/): “Differential Pressure Tolerance ( ±10% + 5 Pa ) or ( 10 Pa + 5 Pa ) whichever is greater” - [SYNTHETIC FRAME ZIG-ZAG FILTER (METAL FREE)](https://www.ulpatek.com/products/coarse-filtration/synthetic-frame-zig-zag-filter-metal-free/): Pre-filter for ventilation equipment and HVAC Highly effective with coarse dust Robust construction with synthetic frame Highly resistant to moisture Disposable Simple and light weight Higher filtration area Energy efficient Longer lifespan with high holding capacity Hot-melt reinforced pleats Filter Standard:ISO 16890Rec. Final Pressure Drop EN13053:Initial ΔP +50 Pa or initial ΔP x3 whichever is lower Filter Class: ISO CoarseMax. Operating Temperature: 80 °C Media:Synthetic FiberStandard depth:48–96 mm Frame:Synthetic Filter TypeFilter ClassMediaCapacityDimensions (mm) GZ-S-H : Synthetic Frame Zig-Zag Filter (Metal Free)G4S : SyntheticH: High592x592x48 Filter ModelEN 779 (cancelled)ISO 16890Dimensions WxHxD (mm)Filtration Area (m²)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) GZ-G4-S-H-287-287-48G4Coarse 65%287x287x480.385075 GZ-G4-S-H-287-592-48G4Coarse 65%287x592x480.6170075 GZ-G4-S-H-490-592-48G4Coarse 65%490x592x480.9260075 GZ-G4-S-H-592-592-48G4Coarse 65%592x592x481.2340075 “Other dimensions are available on request.” “Differential Pressure Tolerance ( ±10% + 5 Pa ) or ( 10 Pa + 5 Pa ) whichever is greater” - [FINE DUST FILTER WITH ALUMINIUM SEPARATOR (MDF FRAME)](https://www.ulpatek.com/products/fine-dust-filtration/fine-dust-filter-with-aluminium-seperator-mdf-frame/): Capturing fine particles Static electricity grounding (optional) Corrugated aluminium separator Robust construction Filter Standard:ISO 16890Max. Operating Temperature:80 °C Filter Class:ISO ePM1 - ISO ePM2,5 - ISO ePM10Gasket:Silicon, EPDM and PU Foam Media: Glass fiberSealing Compound:Two component polyurethane, glass fiber Frame: MDFSeparators:Corrugated Aluminium Rec. Final Pressure Drop EN13053:Initial ΔP +100 Pa or initial ΔP x3 whichever is lower Filter TypeFilter ClassFrameStatic Electricity Grounding CableDimensions (mm)FaceguardGasket FCA : Fine Dust Filter with Aluminium Separator (MDF Frame)M6 F7 F8 F9M: MDFSG: Exist W: Without610x610x292FW: Without FC: On Clean Side FD: On Dirty Side FB: On Both SidesW: Without P: Continuous Pu Foam PP: Pu Foam on Both Side E: EPDM Flat EE: EPDM Flat on Both Side C: Continuous Grey EPDM CC: Grey EPDM on Both Side S: Silicon SS: Silicon on Both Sides Filter ModelEN 779 (cancelled)ISO 16890Dimensions WxHxD (mm)Filtration Area (m²)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) FCA-M6-M-W-305-610-292-FW-WM6ePM10 70%305x610x2928,5170085 FCA-M6-M-W-610-610-292-FW-WM6ePM10 70%610x610x29217340085 FCA-F7-M-W-305-610-292-FW-WF7ePM1 55%305x610x2928,51700110 FCA-F7-M-W-610-610-292-FW-WF7ePM1 55%610x610x292173400110 FCA-F8-M-W-305-610-292-FW-WF8ePM1 70%305x610x2928,51700125 FCA-F8-M-W-610-610-292-FW-WF8ePM1 70%610x610x292173400125 FCA-F9-M-W-305-610-292-FW-WF9ePM1 80%305x610x2928,51700150 FCA-F9-M-W-610-610-292-FW-WF9ePM1 80%610x610x292173400150 “Other dimensions are available on request.” “Differential Pressure Tolerance ( ±10% + 5 Pa ) or ( 10 Pa + 5 Pa ) whichever is greater” - [TERMINAL HEPA FILTER (WITH DIVIDER)](https://www.ulpatek.com/products/absolute-filtration/terminal-hepa-filter-with-divider/): Final filter for cleanrooms Life science Microelectronics Self-contained air inlet, no additional housing required Adjustable airflow by means of a damper Differential pressure (∆P) port and 100% upstream aerosol test port (accessible from technical or room side) High quality glass fiber media Guaranteed leak-free Individual test certificate (acc. to EN 1822 - ISO 29463) Filter Standard:EN 1822 and ISO 29463Max. Operating Temperature:80 °C Filter Class:H13 - H14 - U15Faceguard:Aluminium sheet (powder coated) Media:High quality glass fiberSealing Compound: Two component polyurethane Frame:Anodized extruded aluminiumSeparator:Hotmelt Rec. Final Pressure Drop:Initial pressure drop x2, (max. 600 Pa) Filter TypeFilter ClassPleat HeightDividerAdjustable MechanismDimensions (mm)Spigot DiameterFaceguardGasket HTH : Terminal HEPA Filter with DividerH13 H14 U151: 50 mm 6: 100 mmW: Without D: ExistW: Without AFM: Exist610x610x125A: 125 B: 150 C: 160 D: 200 M: 250 F: 300 L: 315 X: 355 Z: SpecialFC: On Clean SideW: Without P: Continuous Pu Foam E: EPDM Flat Filter ModelEN 1822ISO 29463Dimensions WxHxD (mm)Spigot Diameter (mm)Filtration Area (m²)Pleat Height (mm)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) HTH-H13-1-D-AFM-305-305-125-CH13ISO 35 H305x305x1251602,85015090 HTH-H13-1-D-AFM-305-610-125-DH13ISO 35 H305x610x1252005,55030090 HTH-H13-1-D-AFM-457-457-125-DH13ISO 35 H457x457x1252006,25034090 HTH-H13-1-D-AFM-610-610-125-DH13ISO 35 H610x610x12520011,05060090 HTH-H13-1-D-AFM-610-915-125-MH13ISO 35 H610x915x12525016,55090090 HTH-H13-1-D-AFM-610-1220-125-MH13ISO 35 H610x1220x12525022,050120090 HTH-H14-1-D-AFM-305-305-125-CH14ISO 45 H305x305x1251602,850150115 HTH-H14-1-D-AFM-305-610-125-DH14ISO 45 H305x610x1252005,550300115 HTH-H14-1-D-AFM-457-457-125-DH14ISO 45 H457x457x1252006,250340115 HTH-H14-1-D-AFM-610-610-125-DH14ISO 45 H610x610x12520011,050600115 HTH-H14-1-D-AFM-610-915-125-MH14ISO 45 H610x915x12525016,550900115 HTH-H14-1-D-AFM-610-1220-125-MH14ISO 45 H610x1220x12525022,0501200115 HTH-U15-1-D-AFM-305-305-125-CU15ISO 55 U305x305x1251602,850150135 HTH-U15-1-D-AFM-305-610-125-DU15ISO 55 U305x610x1252005,550300135 HTH-U15-1-D-AFM-457-457-125-DU15ISO 55 U457x457x1252006,250340135 HTH-U15-1-D-AFM-610-610-125-DU15ISO 55 U610x610x12520011,050600135 HTH-U15-1-D-AFM-610-915-125-MU15ISO 55 U610x915x12525016,550900135 HTH-U15-1-D-AFM-610-1220-125-MU15ISO 55 U610x1220x12525022,0501200135 Other dimensions are available on request. Add 15Pa to initial resistance for hood contruction. Filter ModelEN 1822ISO 29463Dimensions WxHxD (mm)Spigot Diameter (mm)Filtration Area (m²)Pleat Height (mm)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) HTH-H13-6-AFM-305-305-175-CH13ISO 35 H305x305x1751604,510015065 HTH-H13-6-AFM-305-610-175-DH13ISO 35 H305x610x1752009,010030065 HTH-H13-6-AFM-457-457-175-DH13ISO 35 H457x457x17520010,110034065 HTH-H13-6-AFM-610-610-175-DH13ISO 35 H610x610x17520018,010060065 HTH-H13-6-AFM-610-915-175-MH13ISO 35 H610x915x17525027,010090065 HTH-H13-6-AFM-610-1220-175-MH13ISO 35 H610x1220x17525036,0100120065 HTH-H14-6-AFM-305-305-175-CH14ISO 45 H305x305x1751604,710015080 HTH-H14-6-AFM-305-610-175-DH14ISO 45 H305x610x1752009,410030080 HTH-H14-6-AFM-457-457-175-DH14ISO 45 H457x457x17520010,510034080 HTH-H14-6-AFM-610-610-175-DH14ISO 45 H610x610x17520018,810060080 HTH-H14-6-AFM-610-915-175-MH14ISO 45 H610x915x17525028,210090080 HTH-H14-6-AFM-610-1220-175-MH14ISO 45 H610x1220x17525037,6100120080 HTH-U15-6-AFM-305-305-175-CU15ISO 55 U305x305x1751605,0100150100 HTH-U15-6-AFM-305-610-175-DU15ISO 55 U305x610x17520010,0100300100 HTH-U15-6-AFM-457-457-175-DU15ISO 55 U457x457x17520011,2100340100 HTH-U15-6-AFM-610-610-175-DU15ISO 55 U610x610x17520020,0100600100 HTH-U15-6-AFM-610-915-175-MU15ISO 55 U610x915x17525030,0100900100 HTH-U15-6-AFM-610-1220-175-MU15ISO 55 U610x1220x17525040,01001200100 Other dimensions are available on request. Add 15Pa to initial resistance for hood contruction. - [SYNTHETIC BLUE ZIG-ZAG FILTER](https://www.ulpatek.com/products/coarse-filtration/synthetic-blue-zig-zag-filter/): Pre-filter for ventilation equipment and HVAC Highly effective with coarse dust Robust fiber structure Disposable Simple and light weight Moisture resistant cardboard Various capacity options enable energy-efficient models with high dust holding capacity (H model) Filter Standard:ISO 16890Rec. Final Pressure Drop EN13053:Initial ΔP +50 Pa or initial ΔP x3 whichever is lower Filter Class: ISO CoarseMax. Operating Temperature:80 °C Media:Synthetic BlueStandard depth:48–96 mm Frame:Cardboard Filter TypeFilter ClassFrameMediaCapacityDimensions (mm) GZ-C-PB : Synthetic Blue Zig-Zag FilterG4C: CardboardPB: Synthetic BlueM Standard H: High592x592x48 Filter ModelEN 779 (cancelled)ISO 16890Media MaterialDimensions WxHxD (mm)Filtration Area (m²)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) GZ-G4-C-PB-M-287-287-48G4Coarse 55%Synthetic Blue287x287x480.285080 GZ-G4-C-PB-M-287-592-48G4Coarse 55%Synthetic Blue287x592x480.4170080 GZ-G4-C-PB-M-592-592-48G4Coarse 55%Synthetic Blue592x592x480.8340080 GZ-G4-C-PB-M-287-287-96G4Coarse 55%Synthetic Blue287x287x960.485055 GZ-G4-C-PB-M-287-592-96G4Coarse 55%Synthetic Blue287x592x960.6170055 GZ-G4-C-PB-M-592-592-96G4Coarse 55%Synthetic Blue592x592x961.3340055 GZ-G4-C-PB-H-287-287-48G4Coarse 55%Synthetic Blue287x287x480.385075 GZ-G4-C-PB-H-287-592-48G4Coarse 55%Synthetic Blue287x592x480.6170075 GZ-G4-C-PB-H-592-592-48G4Coarse 55%Synthetic Blue592x592x481.2340075 GZ-G4-C-PB-H-287-287-96G4Coarse 55%Synthetic Blue287x287x960.585050 GZ-G4-C-PB-H-287-592-96G4Coarse 55%Synthetic Blue287x592x960.9170050 GZ-G4-C-PB-H-592-592-96G4Coarse 55%Synthetic Blue592x592x961.9340050 “Other dimensions are available on request.” “Differential Pressure Tolerance ( ±10% + 5 Pa ) or ( 10 Pa + 5 Pa ) whichever is greater” - [TERMINAL HEPA FILTER (WITHOUT DIVIDER)](https://www.ulpatek.com/products/absolute-filtration/hepa-terminal-hood-filter/): Final filter for cleanrooms Life science Microelectronics Food & Beverages Self-contained air inlet, no additional housing required Differential pressure (∆P) port and 100% upstream aerosol test port (accessible from technical or room side) High quality glass fiber media Guaranteed leak-free Individual test certificate (acc. to EN 1822 - ISO 29463) Optimized velocity distribution Filter Standard: EN 1822 and ISO 29463Max. Operating Temperature:80 °C Filter Class:H13 - H14 - U15Faceguard:Aluminium sheet (powder coated) Media:High quality glass fiberSealing Compound: Two component polyurethane Frame: Anodized extruded aluminiumSeparator: Hotmelt Rec. Final Pressure Drop:Initial pressure drop x2, (max. 600 Pa) Filter TypeFilter ClassPleat HeightDimensions (mm)Spigot DiameterFaceguardGasket HTH : Terminal HEPA Filter without DividerH13 H14 U151: 50 mm 6: 100 mm610x610x125A: 125 B: 150 C: 160 D: 200 M: 250 F: 300 L: 315 X: 355 Z: SpecialFC: On Clean SideP: Continuous Pu Foam Filter ModelEN 1822ISO 29463Dimensions WxHxD (mm)Spigot Diameter (mm)Filtration Area (m²)Pleat Height (mm)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) HTH-H13-1-305-305-125-C-FC-WH13ISO 35 H305x305x1251602,85015090 HTH-H13-1-305-610-125-D-FC-WH13ISO 35 H305x610x1252005,55030090 HTH-H13-1-457-457-125-D-FC-WH13ISO 35 H457x457x1252006,25034090 HTH-H13-1-610-610-125-D-FC-WH13ISO 35 H610x610x12520011,05060090 HTH-H13-1-610-915-125-M-FC-WH13ISO 35 H610x915x12525016,55090090 HTH-H13-1-610-1220-125-M-FC-WH13ISO 35 H610x1220x12525022,050120090 HTH-H14-1-305-305-125-C-FC-WH14ISO 45 H305x305x1251602,850150115 HTH-H14-1-305-610-125-D-FC-WH14ISO 45 H305x610x1252005,550300115 HTH-H14-1-457-457-125-D-FC-WH14ISO 45 H457x457x1252006,250340115 HTH-H14-1-610-610-125-D-FC-WH14ISO 45 H610x610x12520011,050600115 HTH-H14-1-610-915-125-M-FC-WH14ISO 45 H610x915x12525016,550900115 HTH-H14-1-610-1220-125-M-FC-WH14ISO 45 H610x1220x12525022,0501200115 HTH-U15-1-305-305-125-C-FC-WU15ISO 55 U305x305x1251602,850150135 HTH-U15-1-305-610-125-D-FC-WU15ISO 55 U305x610x1252005,550300135 HTH-U15-1-457-457-125-D-FC-WU15ISO 55 U457x457x1252006,250340135 HTH-U15-1-610-610-125-D-FC-WU15ISO 55 U610x610x12520011,050600135 HTH-U15-1-610-915-125-M-FC-WU15ISO 55 U610x915x12525016,550900135 HTH-U15-1-610-1220-125-M-FC-WU15ISO 55 U610x1220x12525022,0501200135 “Other dimensions are available on request.” “Differential Pressure Tolerance ±10%” Filter ModelEN 1822ISO 29463Dimensions WxHxD (mm)Spigot Diameter (mm)Filtration Area (m²)Pleat Height (mm)Nominal Airflow (m³/h)Initial Pressure Drop (Pa) HTH-H13-6-305-305-175-C-FC-WH13ISO 35 H305x305x1751604,510015065 HTH-H13-6-305-610-175-D-FC-WH13ISO 35 H305x610x1752009,010030065 HTH-H13-6-457-457-175-D-FC-WH13ISO 35 H457x457x17520010,110034065 HTH-H13-6-610-610-175-D-FC-WH13ISO 35 H610x610x17520018,010060065 HTH-H13-6-610-915-175-M-FC-WH13ISO 35 H610x915x17525027,010090065 HTH-H13-6-610-1220-175-M-FC-WH13ISO 35 H610x1220x17525036,0100120065 HTH-H14-6-305-305-175-C-FC-WH14ISO 45 H305x305x1751604,710015080 HTH-H14-6-305-610-175-D-FC-WH14ISO 45 H305x610x1752009,410030080 HTH-H14-6-457-457-175-D-FC-WH14ISO 45 H457x457x17520010,510034080 HTH-H14-6-610-610-175-D-FC-WH14ISO 45 H610x610x17520018,810060080 HTH-H14-6-610-915-175-M-FC-WH14ISO 45 H610x915x17525028,210090080 HTH-H14-6-610-1220-175-M-FC-WH14ISO 45 H610x1220x17525037,6100120080 HTH-U15-6-305-305-175-C-FC-WU15ISO 55 U305x305x1751605,0100150100 HTH-U15-6-305-610-175-D-FC-WU15ISO 55 U305x610x17520010,0100300100 HTH-U15-6-457-457-175-D-FC-WU15ISO 55 U457x457x17520011,2100340100 HTH-U15-6-610-610-175-D-FC-WU15ISO 55 U610x610x17520020,0100600100 HTH-U15-6-610-915-175-M-FC-WU15ISO 55 U610x915x17525030,0100900100 HTH-U15-6-610-1220-175-M-FC-WU15ISO 55 U610x1220x17525040,01001200100 “Other dimensions are available on request.” “Differential Pressure Tolerance ±10%” ## 3D FlipBook - [ULPAIR](https://www.ulpatek.com/3d-flip-book/ulpair/) ## Testimonials