Applications

  • Final filter for cleanrooms and LF Units
  • Suitable for Fan Filter Units
  • Life science
  • Healthcare
  • Microelectronics
  • Food & Beverages

Highlights

  • High quality glass fiber media
  • Guarenteed leak free
  • Individiual test certificate (acc. to EN 1822 – ISO 29463)
  • Optimized velocity distribution

Technical Specifications

Filter Standard:EN 1822 and ISO 29463 Max. Operating Tempature: 80˚C
Filter Class:H13 - H14Faceguard:Aluminium sheet (powder coated)
Media: High quality glass fiberGasket: PU foam
Frame:Anodized extruded aluminiumSealing Compound:Two component polyurethane
Rec. Final Pressure Drop:Initial pressure drop x2,
(max. 600 Pa)
Seperator:Hotmelt

Order Code

Filter TypeFilter
Class
Frame Pleat
Height
DesignDimensions
(mm)
FaceguardGasket
HC : HEPA Ceiling
Filter
(Knife Edge Profile)
H13
H14
A: Aluminium1: 50 mm
3: 75 mm
SM: Seperated610x610x89FB: On Both SidesP: Continuous
Pu Foam

HEPA CEILING FILTER (KNIFE EDGE PROFILE/89)

Filter ModelEN 1822ISO 29463Dimensions
WxHxD
(mm)
Filtration
Area
(m²)
Pleat
Height
(mm)
Nominal
Airflow
(m³/h)
Initial
Pressure Drop
(Pa)
HC-H13-A-SM-1-305-305-89-FB-PH13ISO 35 H305x305x892,350150100
HC-H13-A-SM-1-305-610-89-FB-PH13ISO 35 H305x610x894,550300100
HC-H13-A-SM-1-457-457-89-FB-PH13ISO 35 H457x457x89550340100
HC-H13-A-SM-1-610-610-89-FB-PH13ISO 35 H610x610x89950600100
HC-H13-A-SM-1-610-915-89-FB-PH13ISO 35 H610x915x8913,550900100
HC-H13-A-SM-1-610-1220-89-FB-PH13ISO 35 H610x1220x8918501200100
HC-H14-A-SM-1-305-305-89-FB-PH14ISO 45 H305x305x892,450150125
HC-H14-A-SM-1-305-610-89-FB-PH14ISO 45 H305x610x894,750300125
HC-H14-A-SM-1-457-457-89-FB-PH14ISO 45 H457x457x895,350340125
HC-H14-A-SM-1-610-610-89-FB-PH14ISO 45 H610x610x899,450600125
HC-H14-A-SM-1-610-915-89-FB-PH14ISO 45 H610x915x891450900125
HC-H14-A-SM-1-610-1220-89-FB-PH14ISO 45 H610x1220x8918,8501200125

“Other dimensions are available on request.”
“Differential Pressure Tolerance ±10%”

HEPA CEILING FILTER (KNIFE EDGE PROFILE/109)

Filter ModelEN 1822ISO 29463Dimensions
WxHxD
(mm)
Filtration
Area
(m²)
Pleat
Height
(mm)
Nominal
Airflow
(m³/h)
Initial
Pressure Drop
(Pa)
HC-H13-A-SM-3-305-305-109-PH13ISO 35 H305x305x1093,47515075
HC-H13-A-SM-3-305-610-109-PH13ISO 35 H305x610x1096,87530075
HC-H13-A-SM-3-457-457-109-PH13ISO 35 H457x457x1097,67534075
HC-H13-A-SM-3-610-610-109-PH13ISO 35 H610x610x10913,57560075
HC-H13-A-SM-3-610-915-109-PH13ISO 35 H610x915x10920,37590075
HC-H13-A-SM-3-610-1220-109-PH13ISO 35 H610x1220x1092775120075
HC-H14-A-SM-3-305-305-109-PH14ISO 45 H305x305x1093,57515090
HC-H14-A-SM-3-305-610-109-PH14ISO 45 H305x610x1097,17530090
HC-H14-A-SM-3-457-457-109-PH14ISO 45 H457x457x1097,97534090
HC-H14-A-SM-3-610-610-109-PH14ISO 45 H610x610x10914,17560090
HC-H14-A-SM-3-610-915-109-PH14ISO 45 H610x915x10921,27590090
HC-H14-A-SM-3-610-1220-109-PH14ISO 45 H610x1220x10928,275120090

“Other dimensions are available on request.”
“Differential Pressure Tolerance ±10%”